What size water heater do you need
Sized for one morning's hot water with no reheat in between. A boiler that heats faster can run smaller — that's the panel below.
Assumes a 45 °C rise (10 → 55 °C). A weaker element just takes the slower chip to refill — it won't undersize the tank.
What decides the tank size
Two numbers set the size, and swapping them is the usual mistake. Usage — showers only, or showers and baths — picks the volume off the table below. Household size scales it up from there: more people drawing in the same window need more stored water, not a faster element.
| Occupants | Economical, L | Comfortable, L |
|---|---|---|
| 1 | 50 | 80 |
| 2 | 80 | 100 |
| 3 | 100 | 150 |
| 4 | 120 | 200 |
| 5 | 150 | 250 |
| 6+ | 200 | 300 |
Figures are a general sizing guide, not a manufacturer's own chart — adjust within the range for a household that showers back-to-back versus one that spreads it out.
Reading the calculator
Pick a system type first — storage tank, indirect cylinder, or instant.
For a tank: pick the household size and usage level to get the volume, then the reheat time to get the element or coil power.
For an instant unit: pick the fixture and the incoming water temperature to get the required power.
Why the reheat time changes the element
A tank doesn't need a bigger element to feel bigger — it needs a faster one, or a slower one it's willing to wait for. The calculator fixes the temperature rise at 45 °C (a 10 °C mains to a usable 55 °C) and solves for power, the same way the fusion calculator fixes the iron at 260 °C instead of asking for it: one less number to guess, and one real variable — reheat time — left to choose.
A 150-litre tank reheated in three hours needs about 2.6 kW; the same tank left overnight on a six-hour timer gets there on half that. Neither number is wrong — a weaker element just means waiting longer, it never undersizes the tank itself.
Indirect cylinders: volume applies, power doesn't
An indirect cylinder uses the same volume table as an electric one — the coil heats the same stored water the same tank holds. What changes is the power side: there's no element to size, because the coil's output is whatever the heating boiler and its loading pump can deliver to it, not a number this page can calculate.
That's why the second panel switches to a note instead of a kW figure once indirect is picked. The boiler's own rating and the coil's size are the real limits — see how the coil, loading pump and open-vented tanks fit together in the guide below.
Instant and tankless: power follows the tap
A tankless unit stores nothing, so its number isn't litres — it's the power to raise a flow rate by a temperature rise, calculated the moment the tap opens. A shower at 8 litres a minute needs more than twice the power of a basin tap at 4, and a cold winter mains needs more rise than mild incoming water.
The calculator above sizes one fixture at a time, on purpose. A unit sized for a shower alone has no spare capacity for a kitchen tap opening at the same moment — real multi-fixture sizing means adding up every outlet that could run together, which is a job for whoever's speccing the installation, not a quick number here.
Common sizing mistakes
Picking a tank size for an average day instead of the busiest morning — showers back-to-back cost more hot water than the same three showers spread across two hours.
Choosing an element by habit instead of by reheat time: a 3 kW element reheats a small tank fine and a large one far too slowly for a household that showers in sequence.
Expecting one instant unit to cover a shower and a kitchen tap running together — tankless power is sized per fixture, not per household.
Common questions
What size water heater do I need for a family of 4?
Around 150–200 litres, depending on whether it's showers only or showers plus baths — see the table above. The reheat time then sets the element power: about 3.9 kW for 200 litres reheated in 3 hours, less on an overnight timer.
How many kW does a 150 litre water heater need?
About 2.6 kW reheated in 3 hours, or around 1.3 kW left overnight on a 6-hour timer — the calculator above fixes the temperature rise at 45 °C and solves for power either way.
What size instant water heater do I need for a shower?
Around 14 kW on a cold winter mains, or about 10 kW with milder incoming water — a shower draws roughly 8 litres a minute, and the power scales with how much the incoming water needs to rise.
Does an indirect cylinder need its own element wattage?
No — an indirect cylinder has no element. Its heat comes from the boiler through a coil, so the figure that matters is the boiler's own output and the loading pump, not a kW number sized the way an electric tank's is.
Why doesn't the calculator size a tankless unit for the whole house at once?
Because sizing for simultaneous fixtures is a different, higher-stakes calculation — add every outlet that could run together and the number needed to not run cold climbs fast. This tool sizes one fixture at a time; a whole-house tankless installation is worth planning with whoever specs it.