Open the builder
TOOL

What size water heater do you need

Updated: 2026-11-16
System type
Occupants & usage
Tank volume —

Sized for one morning's hot water with no reheat in between. A boiler that heats faster can run smaller — that's the panel below.

Reheat power
Element / coil power —

Assumes a 45 °C rise (10 → 55 °C). A weaker element just takes the slower chip to refill — it won't undersize the tank.

A tank sized by headcount and an element sized by wattage answer two different questions — undersize either one and the house runs out of hot water on the same morning, just for a different reason. Pick a system type above and the two panels answer both at once, with the reheat time or incoming temperature baked into the number instead of hidden behind it.

What decides the tank size

Two numbers set the size, and swapping them is the usual mistake. Usage — showers only, or showers and baths — picks the volume off the table below. Household size scales it up from there: more people drawing in the same window need more stored water, not a faster element.

OccupantsEconomical, LComfortable, L
15080
280100
3100150
4120200
5150250
6+200300

Figures are a general sizing guide, not a manufacturer's own chart — adjust within the range for a household that showers back-to-back versus one that spreads it out.

Reading the calculator

Pick a system type first — storage tank, indirect cylinder, or instant.

For a tank: pick the household size and usage level to get the volume, then the reheat time to get the element or coil power.

For an instant unit: pick the fixture and the incoming water temperature to get the required power.

Why the reheat time changes the element

A tank doesn't need a bigger element to feel bigger — it needs a faster one, or a slower one it's willing to wait for. The calculator fixes the temperature rise at 45 °C (a 10 °C mains to a usable 55 °C) and solves for power, the same way the fusion calculator fixes the iron at 260 °C instead of asking for it: one less number to guess, and one real variable — reheat time — left to choose.

A 150-litre tank reheated in three hours needs about 2.6 kW; the same tank left overnight on a six-hour timer gets there on half that. Neither number is wrong — a weaker element just means waiting longer, it never undersizes the tank itself.

Indirect cylinders: volume applies, power doesn't

An indirect cylinder uses the same volume table as an electric one — the coil heats the same stored water the same tank holds. What changes is the power side: there's no element to size, because the coil's output is whatever the heating boiler and its loading pump can deliver to it, not a number this page can calculate.

That's why the second panel switches to a note instead of a kW figure once indirect is picked. The boiler's own rating and the coil's size are the real limits — see how the coil, loading pump and open-vented tanks fit together in the guide below.

Instant and tankless: power follows the tap

A tankless unit stores nothing, so its number isn't litres — it's the power to raise a flow rate by a temperature rise, calculated the moment the tap opens. A shower at 8 litres a minute needs more than twice the power of a basin tap at 4, and a cold winter mains needs more rise than mild incoming water.

The calculator above sizes one fixture at a time, on purpose. A unit sized for a shower alone has no spare capacity for a kitchen tap opening at the same moment — real multi-fixture sizing means adding up every outlet that could run together, which is a job for whoever's speccing the installation, not a quick number here.

Common sizing mistakes

Picking a tank size for an average day instead of the busiest morning — showers back-to-back cost more hot water than the same three showers spread across two hours.

Choosing an element by habit instead of by reheat time: a 3 kW element reheats a small tank fine and a large one far too slowly for a household that showers in sequence.

Expecting one instant unit to cover a shower and a kitchen tap running together — tankless power is sized per fixture, not per household.

Common questions

What size water heater do I need for a family of 4?

Around 150–200 litres, depending on whether it's showers only or showers plus baths — see the table above. The reheat time then sets the element power: about 3.9 kW for 200 litres reheated in 3 hours, less on an overnight timer.

How many kW does a 150 litre water heater need?

About 2.6 kW reheated in 3 hours, or around 1.3 kW left overnight on a 6-hour timer — the calculator above fixes the temperature rise at 45 °C and solves for power either way.

What size instant water heater do I need for a shower?

Around 14 kW on a cold winter mains, or about 10 kW with milder incoming water — a shower draws roughly 8 litres a minute, and the power scales with how much the incoming water needs to rise.

Does an indirect cylinder need its own element wattage?

No — an indirect cylinder has no element. Its heat comes from the boiler through a coil, so the figure that matters is the boiler's own output and the loading pump, not a kW number sized the way an electric tank's is.

Why doesn't the calculator size a tankless unit for the whole house at once?

Because sizing for simultaneous fixtures is a different, higher-stakes calculation — add every outlet that could run together and the number needed to not run cold climbs fast. This tool sizes one fixture at a time; a whole-house tankless installation is worth planning with whoever specs it.